As data center equipment densities continue to increase, so does the thermal management challenge for operations and facilities managers. Airflow distribution within the data center has a significant impact on the thermal environment. CPI offers both active and passive cooling solutions to manage airflow within your enclosure. For maximum cooling, flexibility and future growth, you may want to consider the TeraFrame Family of Cabinets, which uses CPI Passive Cooling Solutions. CPI Passive Cooling™ Solutions, which include many of the products below, is your green choice for delivering eco-friendly data center solutions. See how Passive Cooling can increase your cooling capacities for less expense by entering your specific data center data into the CPI PUE Calculator. |
|
 |
– delivers unprecedented cooling performance in high-density computing applications Combines Vertical Exhaust Duct, Airflow Director, Air Dam Kit and a solid rear door to deliver managed exhaust airflow Supports extreme heat loads – 30 kW Prevents hot and cold air from mixing within the cabinet Prevents hot exhaust air from recirculating over or around cabinet and entering front of equipment Delivers uniformly cold intake air temperatures to all equipment when fully implemented across data center Maximizes efficiency of air conditioning Use with High-Flow Perforated Metal Door on the front of the cabinet and appropriately sized Filler Panels (blanking panels) to close open rack-mount spaces (RMU) between equipment Can also be deployed without a front door Available on: Read more in CPI’s White Paper: Ducted Exhaust Cabinet – Manage Exhaust Airflow Beyond Hot Aisle/Cold Aisle
|
|
Air Dam Kit– for systems that receive cold air through the front door of the cabinet |
|
Air Diverter Kit– for systems that receive cool air through the bottom of the cabinet - Guides cold air from the bottom of the cabinet to the front of equipment
- Creates an airflow barrier between the door and equipment along the top, bottom and sides of the cabinet
- Prevents hot and cold air from mixing within the cabinet
- Use with Solid Metal, Solid Plexiglass or Vented Plexiglass Door on the front of the cabinet and appropriately sized Filler Panels (blanking panels) to close open rack-mount spaces (RMU) between equipment
- Use Perforated Metal Door or Intelligent Fan Door on the rear of the cabinet
- May be used in combination with the Delphi ECS Enclosure Blower
- Compatible with M-Series MegaFrame, C-Series SlimFrame and T-Series SteelFrame Cabinets
|
|
Internal Air Duct – for systems that receive cool air from a raised floor plenum - Delivers additional cold air from the bottom of the cabinet to equipment at the top half of the cabinet
- Reduces hot spots within the cabinet and recycling of hot exhaust air over the cabinet
- Creates an airflow barrier between the door and equipment along the top, bottom and sides of the cabinet
- Prevents hot and cold air from mixing within the cabinet
- Use with a Perforated Metal Door on the front of the cabinet and appropriately sized Snap-In Filler Panels (blanking panels) to close open rack-mount spaces (RMU) between equipment
- Use with a Perforated Metal Door on the rear of the cabinet
- Compatible with F-Series TeraFrame Cabinet
|
|
Snap-In Filler Panels (blanking panels) – attaches to CPI square-punched equipment mounting rails - Close open rack-mount spaces
- Prevents hot and cold air from mixing within the cabinet
- Attaches to CPI square-punched equipment mounting rails (Multi-Mount Rails) only
- Available for 19"W cabinets only
- 1 RMU or 2 RMU high
- Use with Air Dam Kit or Internal Air Duct
- Compatible with all CPI cabinets with square-punched rails
|
|
Network Switch Exhaust Duct for N-Series TeraFrame – isolates and redirects side exhaust air out fo the rear of the cabinet - Designed to support Cisco 6500 and 9500 switches
- Isolates and redirects hot exhaust air out of the rear of the cabinet to prevent re-circulation of hot air through equipment
- Helps maintain effectivenes of hot aisle/cold aisle data center layouts
- Not available as an accessory; must be ordered when ordering the cabinet
- Compatible with N-Series TeraFrame Network Cabinet
|
|
- guide hot exhaust air out of cabinet and into drop ceiling Use in high-density cabinets to create a closed hot air return between the top of the cabinet and a drop ceiling plenum Telescoping design provides infinite heights ranging from 20" - 60" (508 mm - 1523 mm) Three styles to choose from: For best results use on cabinets with perforated front door, solid side panels, solid rear door, Air Dam Kit and Snap-In Filler Panels in all open RMU space
|
|
- guide hot exhaust air out of cabinet and into drop ceiling
Use in high-density cabinets to create a closed hot air return between the top of the cabinet and a drop ceiling plenum Telescoping design provides infinite heights ranging from 20" - 60" (508 mm - 1523 mm) Must be ordered when ordering the cabinet For best results use on cabinets with perforated front door, solid side panels, solid rear door, Air Dam Kit and Snap-In Filler Panels in all open RMU space
|
|
– directs hot exhaust air up the rear of the cabinet Attaches to the bottom rear of the cabinet Directs hot exhaust air upwards toward the top of the cabinet Use with a Solid Metal Rear Door and Vertical Exhaust Duct to guide hot exhaust air out of the cabinet
|
|
- block bypass air through cable access holes in raised floor tiles Covers cable access holes in raised floor tiles Protects cables as they pass through the hole in the raised floor tile Blocks airflow through cable access holes to improve equipment cooling Available in several styles and sizes
|
|
Delphi ECS Enclosure Blower – lowering cabinet temperatures by delivering cold air from the floor - For increased airflow at the front of cabinets
- Cabinet hot spots lowered by 15°F
- Cold air pulled from floor plenum to server fronts, where cooling air intakes are located
- Only 2 RMU of mounting space required at the bottom of the cabinet
- Five-year life
- UL Recognized
- Patent-pending design
- Best when used with Solid Metal, Solid Plexiglass or Vented Plexiglass Door
- Air Intake Filter and offset intake Blower Duct accessories available
- May be used in combination with Air Dam Kit (recommended) or Air Diverter Kit
- Compatible with M-Series MegaFrame, C-Series SlimFrame and T-Series SteelFrame Cabinets
|
|
MegaFrame® Fan Kit – additional ventilation for MegaFrame, SlimFrame and Seismic Frame Cabinets |
|
T-Series Fan Kit – additional ventilation for SteelFrame Cabinets - Basic ventilation of cabinets placed outside of the traditional data center environment
Quick, easy mounting to the inside of the top panel on standard cabinets (not for use with the Vertical Exhaust Duct) 300 CFM of ventilation provided
|
|
|
|